Description
The WDG-HPII Series offers a unique chimney-effect/convective sampling technology that incorporates the advantages of insitu probe high particulate sampling with high temperature and corrosion resistance of extractive analyzers. The HPII is ideal for combustibles and oxygen measurement on applications in cement and lime kilns, foundry and metals production furnaces, coal, wood waste and heavy oil-fired boilers, black liquor recovery boilers. Available with Series 2000 controller.
Features
- Weatherproof, stainless steel sensor enclosure
- Zirconium oxide oxygen cell
- Catalytic combustibles detector for 0-2000 ppm
- Catalytic methane detector for 0-5%
- Class I, Div. 2 or Class I, Div. 1 option
- Four isolated current outputs
- Four alarms
- Diagnostics
- RS-485
- HART option available
- UL Listed
Specifications
| WDG-IV Series Combustion Analyzers | |
| Principle of Operation (O2) | Zirconium oxide for net oxygen measurement and dual catalytic detectors for both combustibles and methane. |
| Output Range (O2) | Oxygen: From 0-1 to 0-100% |
| Accuracy (O2) | ±0.75% of measured value or ±0.05%, whichever is greater Combustibles: ±2% of full scale output range |
| Response | Oxygen: 90% of a step change < 30 seconds |
| Aspirator Air Requirements | 10-20 SCFH (4.7 to 9.4 L/min) Typical at 15 to 100 psig |
| Analog Output | Two isolated linear current outputs for O2, combustibles and hydrocarbon. Each output can be 4-20 mA, 0-20 mA, 20-4 mA or 20-0 mA and is fully scalable. NAMUR Configurable. Hold or track during calibration. Max. load 1200 Ω |
| Alarms | Two independent oxygen alarms each high or low selectable Set relays to energize or de-energize on alarm |
| Contact Rating | 0.5A, 30V, 10VA max. non-inductive load, AC or DC |
| Digital Communication | 2 wire MODBUS RTU, 57.6 KBaud |
| Configuration | MODBUS RTU, AMETEK configuration software, or AMEVision HMI |
| Diagnostics | Watchdog timer and service alarms. Twenty-entry event log. |
| Calibration | Calibrate or verify calibration. Stored calibration and verification data. Selectable calibration gas run time and process recovery time. Timed automatic calibration with optional Remote Calibration Unit. |
| Sample Pressure | ±10 in. water gauge |
| Max. Sample Dewpoint | 392°F (200°C) |
| Max. Flue Gas Temp. / Probe Type / Lengths | 1300°F (704°C) / 316 SS / 36” – 108”(91 cm – 274 cm) 1875°F (1024°C) / 310 SS / 36” – 108”(91 cm – 274 cm) 3000°F (1648°C) / Hexoloy® / 24” – 72” (60 cm – 182 cm) |
| Environment | Ambient Temp.: -20°C to 71°C Relative Humidity: 10% to 90%, non-condensing |
| Enclosure | Lift-off NEMA 3R, weather resistant, stainless steel. |
| Power Requirements | 115 VAC, ±10%, 47-63 Hz, 740 VA max.; 230 VAC, ±10%, 47-63 Hz, 740 VA max. |
| Calibration Gas Requirements | Use calibration gases @ 10 psig, 1.53 SCFH (0.7 L/min.)
O2 Span Gas: Air or from 1.0% to 100% O2, balance N2 |